16A C20 ServerTech PDU 36 Outlets mixed ( 18xC13 + 18xCX ) Switched POPS
C3WG36RL-0AJE2MT4 16A C20 ServerTech PDU 36 Outlets mixed ( 18xC13 + 18xCX ) Switched POPS
Ke y F e at ur e s
HDOT C x
Cx is the future ready UL tested hybrid of the C13 and C19
outlets accommodating both C20 and C14 plugs.
N e t wo r k Mo ni t o r i ng
Gain access to valuable data through connections including
HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S),
RS-232 serial, and more.
Mul t i Ma s t e r Li nki ng
Multi-Linking Max 16 PDUs can be daisy chained using a USB
or Ethernet connection.
C o l o r Ma t r i x LC D Di s pl a y
Easy-to-read LEDs display current per phase to help prevent
overloads and simplify three-phase load balancing in highdensity cabinets.
Ho t - s wa p C o nt r o l l e r
100% Field Replaceable while hot, no risk of short circuits,
finger safe replacement in the unlikely event of an outage.
Ra mLo c k Lo c ki ng Out l e t s
Receptacles have high retention and are compatible with PLock type power cords.
E nvi r o nme nt a l Mo ni t o r i ng
PRO3X units support a maximum of 12 daisy-chained Raritan
DX2 sensor packages. Receive SNMP-based alerts and e-mail
notifications
P e r - Inl e t P o we r S e ns i ng
Meets ANSI C12.1 for billing-grade accuracy of Current per
phase. PIPS includes voltage, active power, apparent power,
power factor, and energy.
P e r - Out l e t P o we r S e ns i ng
Meets ANSI C12.1 for billing-grade accuracy of Current per
phase. POPS includes voltage, active power, apparent power,
power factor, and energy.
Br a nc h C ur r e nt Mo ni t o r i ng
Monitors current at each breaker branch and provides SNMPbased alerts and emails on high usage that risks a tripped
circuit.
Br a nc h C i r c ui t P r o t e c t i o n
This PDU meets the UL and IEC 60950-1 requirement for
branch circuit protection through use of UL489 rated
magnetic-hydraulic circuit breakers or UL248 fuses.
Out l e t C o nt r o l
On Switched rack PDUs, cycle power to individual outlets or
groups of outlets to reboot servers. Or, power off unused
receptacles.
Hi g h T e mpe r a t ur e Ra t i ng
This product has been tested and approved for safe and
reliable operation in 60 °C data center environments.
Fl e xi bl e Mo unt i ng
Includes standard button mounts along with provisions for
custom mounting brackets (contact Server Technology for
details).
C3WG36RL-0AJE2MT4 16A C20 ServerTech PDU 36 Outlets mixed ( 18xC13 + 18xCX ) Switched POPS
Certifications
Nor t h Amer ican:
cTUVus Mark to UL 60950-1:2007 R10.14
CAN/CSA-C22.2 No. 60950-1-07+A1:2011+A2:2014
FCC Part 15 Subpart B Sections 15.107 and 15.109, Class A
Global:
TUV T-Mark to EN60950-1:2006+A11+A1+A12+A2
EMC to EN55024 (2010) and EN55032 (2012)
CE Compliant
RoHS, EuropeanHazardous Materials Directive (Recast) 2011/65/EU
WEEE Compliant
M easurement Accuracy
Input Meas urement Accuracy:
LED Current = ± 10% at 0.1 amp (0.3 - 9.9 amps) and 1 amp (> 9.9 amps) resolution
GUICurrent = ± 1% at 0.01 amp resolution (above 0.25 amp)
Voltage = ± 1% at 0.1 volt resolution (nominal ± 10%)
Active Power = ± 1% at 1 watt resolution
Apparent Power = ± 1% at 1 volt-amp resolution
Power Factor = ± 3% at 0.01 resolution
Crest Factor = ± 10% at 0.1 resolution
Energy = ± 1% at 0.1 kilowatt-hour resolution
Out put Measurement Accuracy
GUI Current = ± 1% at 0.01 amp resolution (above 0.15 amp)
Voltage = ± 1% at 0.1 volt resolution (nominal ± 10%)
Active Power = ± 1% at 1 watt resolution
Apparent Power = ± 1% at 1 volt-amp resolution
Power Factor = ± 3% at 0.01 resolution
Crest Factor = ± 10% at 0.1 resolution
Energy = ± 1% at 1 watt-hour resolution
Optional Accessor es
Raritan SmartSensor: Temperature (DX2-T1), Temperature and Humidity (DX2-T1H1,DX2-T2H1,DX2-T2H2,DX2-T3H1),Dual Contact Closure (DX2-
CC2), and Intelligent Door Sensor (DX2-DH2C2)
Buttons (KIT-0020) included for tool-less mounting (see diagram)
See the Mounting Bracket Guide for further suggestions
See also version : C3WG36RL-EPJE2MT4